CODE INDICATION
05 Refrig. Cabinet Thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s
06 Refrig. Evaporator Thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s
07 Freezer Cabinet Thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s
08 Freezer Evaporator Thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s
20 Defrost Under-heat with No Voltage Feedback Through Gray/White Wire at Defrost Start
21 Defrost Overheat
22 No Voltage Feedback Through Gray/White Wire at Defrost Start
23 Defrost Overheat with No Voltage Feedback through Gray/White Wire at Defrost Start
24 Defrost Under-heat
30 Excessive Icemaker Water Valve Solenoid Activation (Exceeded 15 Seconds)
40 Excessive Freezer Compressor Run
50 Excessive Refrigerator Compressor Run
NOTE: If a refrigerator evaporator thermistor is faulty, the refrigerator compressor is not energized until compartment air temperature exceeds high offset by 5°F (3°C). SERVICE flashes and Error Code 06 is logged.