James says his gas oven stopped working but the stove still works (I think)

James wrote:

ge gas, model jgbs20bea1wh, oven ing. lites up gas valve has 2.8 ac. oven worked fine till removed painted wall installed gas line top works fine oven stoped

Hi, James. Well, I am trying to understand your cryptic e-mail to me made even more difficult to understand by your sparse use of punctuation. But if I am interpreting it correctly it sounds like maybe you’re getting 2.8 amps of current to the igniter? You did not say what you were actually measuring, you just said “2.8 ac”, I don’t know whether that is current or voltage. “AC” stands for “alternating current” which is a common type of household electrical supply. But AC can be measured in watts (power), voltage, current (amps), usage over time (kw-hours), etc.

I will assume that you measured current since what you reported is a typical under current reading thru a gas range ignitor. Assuming that this is the case, the solution would be to replace the igniter. Here’s the part link to the ignitor you need to fix your oven ==> http://www.repairclinic.com/PartDetail/Oven-Igniter/WB13K21/2494?modelNumber=JGBS20BEA1WH

A good igniter will draw a minimum current of at least 3.2 amps. Since yours is well below that, this would indicate that there is insufficient current flowing through the igniter to open the gas valve and let gas through to the bake burner tube.

I’m not sure about your reference to a painted wall. I will assume that you are referring to cabinetry around the oven that was changed or modified. If so, this in itself should have no effect whatsoever on the operation of the oven bake ignitor. It could however have an affect on the cooling of the oven if there were insufficient ventilation. But again, this does not affect the ignition of the bake burner.


 